- 현재 위치
- HOME > Thermo Scientific > 세포 배양

CellEvent™ Senescence Green Flow Cytometry Assay Kit, 200 Assays
Invitrogen™ · Flow Cytometry
The CellEvent Senescence Green Flow Cytometry Assay Kit enables flow cytometric detection of cellular senescence via β-galactosidase hydrolysis. The kit contains an optimized buffer and a fluorescein-based reagent that contains two galactoside moieties, making it a specific target for β-galactosidase. Activation of β-galactosidase is commonly used as a biomarker for senescent cells. This hydrolase enzyme resides in lysosomes and converts β-galactosides into monosaccharides under acidic pH conditions. The enzyme-cleaved product is retained within the cell due to covalent binding of intracellular proteins and emits a fluorogenic signal that has absorption/emission maxima of 490/514 nm. CellEvent Senescence Green Flow Cytometry Assay Kit features include: • Fluorescent detection of β-galactosidase hydrolysis by flow cytometry • Fixed cell assay • Multi-color compatibility When normal cells reach the end of their limited replicative lifespan, commonly referred to as the Hayflick limit, they enter into a senescent phase where they remain metabolically active without undergoing cell death processes. These senescent cells adopt a specific phenotypic state that includes the appearance of multi-nucleated cells, increased vacuolization, expression of pH-dependent β-galactosidase, and morphological changes where cells become enlarged and extended. Through a variety of mechanisms, they may play a role in tumor suppression, tumor progression, aging, and tissue repair. β-galactosidase resides in lysosomes and converts β-galactosides into monosaccharides under acidic pH conditions. The activity is optimal under lysosomal pH 4, but conventional assays measure at pH 6. It has been shown that normalized β-galactosidase activity is twice as high in senescent cells as in presenescent cells regardless of the pH value used for testing. Traditionally, the colorimetric substrate for β-galactosidase, 5-bromo-4-chloro-3-indolyl-β-D-galactopyranoside (x-gal), has long been used to detect metabolic activity in cells in vitro. Upon hydrolysis by β-galactosidase, x-gal converts to a blue precipitate, which is not suitable for flow cytometric assays. Therefore, we have developed a sensitive, fluorescent substrate for β-galactosidase that can be used in flow cytometry assays for the detection of senescent cells.
제품 사양
| 검출 방법 | Fluorescence |
|---|---|
| 수량 | 200 Assays |
| 색상 | Green |
| Emission | 488/514 |
| 용도(애플리케이션) | Flow Cytometry |
| 용도 (장비) | Flow Cytometer |
| 제품라인 | CellEvent |
| 제품 유형 | Flow Cytometry Assay Kit |
| Unit Size | Each |
규격 / 옵션
| 카탈로그번호 | 규격 |
|---|---|
| C10841 | 200 Assays |
| C10840 | 50 Assays |
필요한 시약, 무엇이든 준비해드립니다.
언제든지 문의해 주세요!
salechem@thelabk.com
납기 및 재고 문의
시약 준비는 저희가!
시약 구매 안내
- 본 제품은 실험·연구용 시약/소모품/장비입니다.
- 유해물질 관련 법령에 따라 미성년자에게는 판매하지 않습니다.
- 유해화학물질 시약은 시험·연구·검사용 용도로만 구매·사용 가능합니다.
- 자세한 내용은 관할 환경청 및 관련 법령을 참조하시기 바랍니다.
- 제이제이코퍼레이션 더랩케미칼
- 수입 발주 후 취소 요청 시, 별도의 취소수수료가 발생될 수 있습니다.
- 일부 택배불가 제품은 퀵으로만 가능하니 고객센터로 문의해 주세요.
배송 안내
- 재고 보유 중인 제품은 오후 2시 이전 결제 시 당일 출고가 가능합니다.
- 드라이아이스 포장 제품 또는 특정 유독물질의 경우 추가 운임이 발생할 수 있습니다.
- 냉동 / 냉장 제품은 공휴일 및 주말 전일에는 출고가 불가합니다.
- 수입 제품은 원료 수급 및 생산이슈로 추가 지연될 가능성이 있습니다.
교환 / 반품 / 취소
- 제품의 하자 또는 누수가 발생한 경우 별도 수수료 없이 교환 및 반품 가능합니다.
- 제품 수령 후 7일 이후 전 제품 교환 또는 반품 불가합니다.
- 제품의 하자를 제외한 모든 반품 및 교환에는 수수료가 부과되며, 택배는 선불로 발송해 주셔야 합니다.
- 냉장 또는 냉동 제품은 어떠한 경우에도 반품 및 교환이 어렵습니다.
- 포장지가 아닌 제품을 개봉한 경우 반품 및 교환이 불가합니다.
궁금하신 점이 있으시면 언제든지 연락 주세요.
- 전화070-7176-5008
- 이메일salechem@thelabk.com