MicroSEQ™ E. coli O157:H7 Detection Starter Kit, with PrepSEQ™ Rapid Spin Sample Preparation Kit
Applied Biosystems™ · Diagnostic Testing
The MicroSEQ™ E. coli O157:H7 Detection Kit detects E. coli O157:H7 simply, reliably, and rapidly in food samples. The assay uses the polymerase chain reaction (PCR) to amplify a unique microorganism-specific DNA target sequence and a TaqMan™ probe to detect the amplified sequence. Key product features: • Enjoy ease-of-use from a streamlined, lyophilized format and a simple, software guided 3-step process • Get your results quickly with time-to-results in as little as 8 hours for a 25g sample • Genome sequencing using the Applied Biosystems SOLiD™ platform helps ensure high specificity • Detect 1-3 colony-forming units (CFU) per 25 grams of food • Get optimal performance on a wide range of food sample and environmental surface types • Eliminate false negatives with internal positive control Lyophilized for Efficiency and Ease of Use For maximum ease of use and consistency of results, the reagents used in the MicroSEQ™ E. coli O157:H7 Detection Kit are lyophilized into preformatted assay beads. The beads hold the active enzyme, the target-specific primer and probe set, Internal Positive Control (IPC), and other reagents for PCR. The IPC is provided to help eliminate false negatives by detecting the presence of materials that can inhibit target amplification. Enhanced Specificity To design an assay highly specific for E. coli O157:H7, the genome of E. coli O55:H7 was sequenced using the next-generation Applied Biosystems™ SOLiD™ platform and compared to the publicly available sequence of E. coli O157:H7. Sequences specific to E. coli O157:H7 were then used as targets to design the MicroSEQ™ E. coli O157:H7 Detection Kit. The MicroSEQ™ E. coli O157:H7 Detection Kit owes its additional specificity to the use of TaqMan™ chemistry. Unlike SYBR™ Green chemistry that uses only target-specific primers, TaqMan™ chemistry uses both primers and probes that are specific to the target to help prevent false positives. Workflow Flexibility To better meet the needs of food testing laboratories, the MicroSEQ™ E. coli O157:H7 Detection Kit offers the flexibility of three different workflows. Fast Time to Results • 8-10 hour time to results • 25 g sample • BHI enrichment Standard Media • 18 hour time to results • 25 g sample • BPW enrichment Larger Volumes • 18 hour time to results • 375 g sample of ground beef or beef trim • BPW enrichment Simple, Three-Step Procedure There is minimal training or prior experience needed for you to perform the assay in these three simple steps. 1. Enrich sample 2. Prepare DNA 3. Run test AOAC Certified The full workflow including the MicroSEQ™ E. coli O157:H7 Detection Kit, PrepSEQ™ sample preparation kits, 7500 Fast instrument and RapidFinder™ Express software has earned the Performance Tested MethodsSM certification from the AOAC Research Institute. Optimized Sample Preparation The MicroSEQ™ E. coli O157:H7 Detection Kit is optimized for use with PrepSEQ™ Sample Preparation Kits. PrepSEQ™ kits reduce pre-enrichment time, enhance assay performance and enable you to enrich and prepare high quality samples from a broad range of sample types for detection of 1-3 CFU per 25 grams of sample. Clear Results using a Software-Guided Procedure After sample enrichment and preparation, RapidFinder™ Express software guides you through the entire workflow with on-screen instructions. Amplification, detection, data collection and analysis are fully automated. When the assay is complete, the software presents an easy-to-read screen that allows you to view the results in each reaction tube. Results are clearly displayed and can be labeled with flags, notifications and prompts that enable you to quickly interpret the data and take appropriate action. A Complete Solution The MicroSEQ™ E. coli O157:H7 Detection Kit is part of a complete food testing solution. The kit includes everything required to run 96 reactions. All components have been designed for rapid implementation in food testing laboratories and performance-verified to make E. coli O15:H7 detection as fast, easy and reliable as possible. For Research Use Only. Not for use in diagnostics procedures.
제품 사양
| 용도(애플리케이션) | Real-Time PCR |
|---|---|
| 라벨 또는 염료 | ROX (Pre-mixed) |
| 수량 | 96 Tests |
| 반응 속도 | Fast |
| 용도 (장비) | StepOnePlus, Fast Mode |
| Unit Size | Each |
필요한 시약, 무엇이든 준비해드립니다.
언제든지 문의해 주세요!
salechem@thelabk.com
납기 및 재고 문의
시약 구매 안내
- 본 제품은 실험·연구용 시약/소모품/장비입니다.
- 유해물질 관련 법령에 따라 미성년자에게는 판매하지 않습니다.
- 유해화학물질 시약은 시험·연구·검사용 용도로만 구매·사용 가능합니다.
- 수입 발주 후 취소 요청 시, 별도의 취소수수료가 발생될 수 있습니다.
- 일부 택배불가 제품은 퀵으로만 가능하니 고객센터로 문의해 주세요.
배송 안내
- 재고 보유 중인 제품은 오후 2시 이전 결제 시 당일 출고가 가능합니다.
- 드라이아이스 포장 제품 또는 특정 유독물질의 경우 추가 운임이 발생할 수 있습니다.
- 냉동 / 냉장 제품은 공휴일 및 주말 전일에는 출고가 불가합니다.
교환 / 반품 / 취소
- 제품의 하자 또는 누수가 발생한 경우 별도 수수료 없이 교환 및 반품 가능합니다.
- 제품 수령 후 7일 이후 전 제품 교환 또는 반품 불가합니다.
- 냉장 또는 냉동 제품은 어떠한 경우에도 반품 및 교환이 어렵습니다.
궁금하신 점이 있으시면 언제든지 연락 주세요.
- 전화070-7176-5008
- 이메일salechem@thelabk.com