
Click-iT™ Plus EdU Cell Proliferation Kit for Imaging, Alexa Fluor™ 647 dye
Invitrogen™ · Cell Viability, Proliferation & Function
Click-iT Plus EdU Cell Proliferation imaging kits have been optimized for fluorescence microscopy applications and are a superior alternative to traditional proliferation assays. In this assay the modified thymidine analogue EdU (5-ethynyl-2'-deoxyuridine, a nucleoside analog of thymidine) is efficiently incorporated into newly synthesized DNA and fluorescently labeled with a bright, photostable Alexa Fluor™ dye in a fast, highly-specific, mild click reaction. Find more tools for image-based detection of proliferating cells > • Simple—works the first time, every time, in less time than traditional methods • Efficient—no denaturation steps or harsh treatment required • Content-rich results—improved preservation of cell morphology, antigen structure, GFP fluorescent signal, and DNA integrity • Consistent—not dependent on variable antibody lots for detection The kit contains all of the components needed to label and detect the incorporated EdU as well as perform cell cycle analysis on samples from adherent cells. For cell cycle analysis, the kit includes a blue fluorescent Hoechst 33342 dye. The kit contains sufficient reagents for labeling 50 18x18 coverslips using 500 μL of reaction buffer per test. Avoid the Harsh Treatments Associated with BrdU Method Measuring changes to cell proliferation is a fundamental method for assessing cell health, determining genotoxicity, and evaluating anti-cancer drugs. The most accurate method of doing this is by directly measuring DNA synthesis. The traditional method utilizes the nucleoside analog BrdU (5-bromo-2'-deoxyuridine, a nucleoside analog of thymidine), which is incorporated into newly transcribed DNA. After incorporation the samples are treated with harsh methods (HCl, heat, or enzymes) to denature the DNA and expose the BrdU molecules to detection by anti-BrdU antibodies. However, the BrdU method to measure cell proliferation is time consuming and difficult to perform consistently. The harsh treatments necessary for this method can adversely affect sample integrity, cell morphology, image quality, and the ability to multiplex. The Click-iT™ Plus EdU assay measures the rate of new DNA synthesis based on incorporation of the nucleoside analog EdU into DNA. Detection is achieved through a catalyzed 'click' reaction that is completed typically within 30 minutes. The click reaction uses bioorthogonal (biologically unique) moieties to fluorescently label proliferating cells, producing low backgrounds and high detection sensitivities. Because of the mild reaction conditions the Click-iT™ Plus assays can accurately determine cell proliferation while preserving cell morphology, DNA integrity, antigen binding sites, and the fluorescent signal from GFP. Preservation of DNA integrity allows for DNA staining, including staining with dyes used for cell cycle analysis.
제품 사양
| 검출 방법 | Fluorescence |
|---|---|
| 염료 유형 | Alexa Fluor™ 647 |
| 형식 | Vial(s) |
| 수량 | 1 kit |
| 용도(애플리케이션) | Cell Viability |
| 용도 (장비) | Fluorescence Microscope |
| 제품라인 | Click-iT |
| 제품 유형 | Cell Proliferation Kit |
| Unit Size | Each |
필요한 시약, 무엇이든 준비해드립니다.
언제든지 문의해 주세요!
salechem@thelabk.com
납기 및 재고 문의
시약 구매 안내
- 본 제품은 실험·연구용 시약/소모품/장비입니다.
- 유해물질 관련 법령에 따라 미성년자에게는 판매하지 않습니다.
- 유해화학물질 시약은 시험·연구·검사용 용도로만 구매·사용 가능합니다.
- 수입 발주 후 취소 요청 시, 별도의 취소수수료가 발생될 수 있습니다.
- 일부 택배불가 제품은 퀵으로만 가능하니 고객센터로 문의해 주세요.
배송 안내
- 재고 보유 중인 제품은 오후 2시 이전 결제 시 당일 출고가 가능합니다.
- 드라이아이스 포장 제품 또는 특정 유독물질의 경우 추가 운임이 발생할 수 있습니다.
- 냉동 / 냉장 제품은 공휴일 및 주말 전일에는 출고가 불가합니다.
교환 / 반품 / 취소
- 제품의 하자 또는 누수가 발생한 경우 별도 수수료 없이 교환 및 반품 가능합니다.
- 제품 수령 후 7일 이후 전 제품 교환 또는 반품 불가합니다.
- 냉장 또는 냉동 제품은 어떠한 경우에도 반품 및 교환이 어렵습니다.
궁금하신 점이 있으시면 언제든지 연락 주세요.
- 전화070-7176-5008
- 이메일salechem@thelabk.com